Feature:

The JLN-740 series is a Doppler Speed Log compliant with the IMO MSC.96(72) standard, required on all internationally-voyaging ships exceeding 300 GT. Boasting never-before-seen accuracy for speed measurement, the JLN-740 is also installed with our company’s proprietary bubble detection, which informs you when measurement accuracy is impaired due to air bubble contact. A model featuring color LCD touch panels for the main and sub displays, allowing you to view important information and adjust brightness in all displays from one location, is also available.

Brochure

Price: Contact

Specifications

Name DOPPLER LOG
Model JLN-740A JLN-740N JLN-741A JLN-741N
IMO approved
Operating system Dual-beam pulse Doppler system
Operation frequency 2MHz
Measurement scale -10.00 to 40.00kn
Sailing display range Model A : 0 to 999999.99NM, Model N : 0 to 99999.99NM (NWW-7 : to 9999.99NM with Distance Counter)
Water speed 3.0 m deeper than the transducer surface
Ship speed accuracy 1 % of the speed of the ship, or 0,1 kn whichever is greater
Total distance accuracy 1 % of the distance run by the ship in 1 h or 0,1 nautical miles in each hour whichever is the greater.
Speed indication kn or m/s
Display Touch panel
5.1 inch-LCD
(480 x 800 pixels)
4.5inch
monochrome
LCD
Touch panel
5.1 inch-LCD
(480 x 800 pixels)
4.5inch
monochrome
LCD
Input interface
(IEC-61162-1)
GPS: RMC, ZDA (clock adjustment)
Signal output 8 ports NMEA0183 Ver1.5, 2.1, 2.3, 4.0 or IEC61162-1 :
VBW, VLW
2 ports IEC61162-1 :
VBW, VLW
1 ports IEC61162-1 :
VBW, VLW
I/O interface Analog display : 2 ports
Log pulse : 2 ports
(Photocoupler signal 200pulse / NM, Max. 30V, 10mA)
Distance Counter (NWW-7) : 1port
Remote Display (NWZ-650SDR /NWZ-840SDR),
Multi Information Display (NWZ-4610) : Total 2 ports
LAN I / O for RMS : 1 ports
Alarm (Power · Speed · System) output : 1 port each
Serial I /O for alarm : 1 port
Dimmer : serial I / O:1 port · Analog Input : 1 port
Power supply voltage AC100/ 230V (±10%)
Power consumption AC100V : 50W (60VA) Less than, AC230V : 50W (150VA) Less than
Environmental requirements
(excl. transducer)
Temperature range : -15 to 55℃ (operating)
Relative humidity : 0 to 93% (non condensing)
JRC JLN-740